USAID Flood Response - Post Intervention Survey 2019-2020
postfloodintervention.Rd
This dataset represents the USAID Flood Response Post Intervention Survey conducted in Mulanje during 2019-2020 using the mWater platform. It contains comprehensive water quality assessments and operational data from various water points affected by flooding.
Format
A tibble with 308 rows and 30 variables:
- submitted_on
Date when the survey was submitted
- water_point_name
Name of the water point
- latitude
Geographic latitude coordinate of the water point
- longitude
Geographic longitude coordinate of the water point
- photo_condition_water_point
File names or URLs of photos illustrating the current condition of the water point
- operational_feel_of_pump
Qualitative assessment of how the pump feels during operation
- time_to_pump_20_litres
Time taken (in seconds or minutes) to pump 20 liters of water
- number_of_strokes_to_yield_water
Number of pump strokes needed to produce water
- sediment_presence
Presence or absence of sediment in the water
- electrical_conductivity_magnitude
Measured magnitude of electrical conductivity in the water sample
- electrical_conductivity_units
Units of electrical conductivity measurement (e.g., μS/cm)
- arsenic_magnitude
Concentration of arsenic detected in the water sample
- arsenic_units
Units used to measure arsenic concentration (e.g., μg/L)
- ammonia_mg_per_l
Ammonia concentration in mg per liter
- fluoride_ppm
Fluoride concentration in parts per million
- nitrate_mg_per_l
Nitrate concentration in mg per liter
- total_dissolved_solids_ppt
Total dissolved solids in parts per thousand
- free_chlorine_mg_per_l
Concentration of free chlorine in mg per liter
- ph
pH level of the water sample (acidity/alkalinity)
- temperature_magnitude
Temperature value of the water sample
- temperature_units
Units for temperature measurement (degree celsius)
- turbidity_tube_magnitude
Measured turbidity of water using a turbidity tube
- turbidity_tube_units
Units for turbidity measurement (e.g., NTU)
- comments
Additional notes or observations related to the water point or sample
- type_of_sample
Type or source of the water sample (e.g., well, tap, river)
- date_of_sample
Date when the water sample was collected
- ecoli_mpn_per_100ml
Most probable number (MPN) of E. coli bacteria per 100 milliliters
- ecoli_upper_95ci_per_100ml
Upper limit of the 95 percent confidence interval for E. coli MPN per 100 ml
- ecoli_health_risk_category
Health risk classification based on E. coli levels (e.g., low, medium, high)
- ecoli_image
File name or URL of image showing E. coli test result or sample compartment color change