USAID Flood Response Rehabilitation and Chlorination Survey
Source:R/floodchlorinationsurvey.R
floodchlorinationsurvey.Rd
This dataset is from the USAID Flood Response Rehabilitation and Chlorination Survey, conducted between 2019 - 2020, to assess and rehabilitate flood-affected boreholes in Malawi. Using the mWater, data collectors captured detailed information on the condition of handpumps, their components, water safety risks, and the impact of chlorination and repairs. The survey was part of an emergency response initiative to restore access to safe drinking water following flood events.
Format
A tibble with 328 rows and 118 variables
- submitted_on
Date when the data was submitted
- water_point_name
Name of the water point
- latitude
Latitude coordinate of the water point
- longitude
Longitude coordinate of the water point
- chlorination_rehab_date
Date chlorination or rehabilitation was conducted
- community_mobilised
Indicates whether the community was mobilized for support
- functional_status_before
Functional status of the water point before intervention
- rating_bolts_nuts
Condition rating of bolts and nuts
- rating_compression_cone
Condition rating of the compression cone
- rating_cylinder
Condition rating of the cylinder
- rating_flapper
Condition rating of the flapper
- rating_footvalve_bobbin
Condition rating of the footvalve bobbin
- rating_footvalve_body
Condition rating of the footvalve body
- rating_footvalve_oring
Condition rating of the footvalve O ring
- rating_fulcrum_pin
Condition rating of the fulcrum pin
- rating_fulcrum_bearings
Condition rating of the fulcrum pin bush bearings
- rating_handle
Condition rating of the pump handle
- rating_hanger_pin
Condition rating of the hanger pin
- rating_hanger_bearings
Condition rating of the hanger pin bush bearings
- rating_head_bolt
Condition rating of the head bolt
- rating_plunger_bobbin
Condition rating of the plunger bobbin
- rating_plunger_body
Condition rating of the plunger body
- rating_plunger_useal
Condition rating of the plunger U seal
- rating_pump_head_case
Condition rating of the pump head case
- rating_pump_head_cover
Condition rating of the pump head cover
- rating_rising_main
Condition rating of the rising main pipe
- rating_rising_centralisers
Condition rating of rising main centralisers
- rating_rods
Condition rating of connecting rods
- rating_rod_centralisers
Condition rating of rod centralisers
- rating_rodhanger
Condition rating of the rod hanger
- rating_rope
Condition rating of the rope
- rating_socket
Condition rating of the socket
- rating_steel_cone
Condition rating of the steel cone
- rating_top_sleeve
Condition rating of the top sleeve
- rod_count
Number of rods in the borehole
- broken_parts_fished_out
Indicates whether broken parts were retrieved from the borehole
- broken_parts_comments
Comments on the broken parts retrieved
- silt_observed
Presence of silt on parts (Yes/No)
- corrosion_observed
Presence of corrosion on parts (Yes/No)
- slime_observed
Presence of slime buildup on parts (Yes/No)
- rising_main_length_m
Length of the rising main pipe in meters
- rope_attached
Indicates whether a rope was attached to the rising main
- photos_of_removed_parts
URLs or filenames of photos showing removed parts
- pedestal_condition
General condition of the pedestal
- pedestal_firm
Is the pedestal held firmly in place?
- photos_of_civil_work
URLs or filenames of photos showing surrounding infrastructure
- latrines_within_30m
Presence of latrines within 30m of the water point
- latrines_within_100m
Presence of latrines within 100m of the water point
- cemetery_within_30m
Presence of cemetery within 30m
- waste_dumps_within_30m
Presence of waste dumps within 30m
- difficult_access_by_car
Whether the site is difficult to reach by car
- chlorination_done
Indicates whether chlorination was conducted
- parts_chlorinated
Indicates whether the parts were chlorinated
- parts_chlorinated_unknown
TRUE if unsure whether parts were chlorinated
- borehole_depth_m
Total depth of the borehole in meters
- water_depth_m
Depth of water in the borehole in meters
- chlorine_water_buckets
Number of 20L buckets of chlorine-treated water used
- hth_dissolved_properly
Whether 1g of HTH was dissolved for every 20L of water
- chlorinated_parts_installed
Were chlorinated parts reinstalled after treatment?
- replaced_rising_main_length_m
Length of rising main pipe replaced (m)
- replaced_rod_count
Number of rods replaced
- replaced_bolts_nuts_tick
TRUE if bolts and nuts were replaced
- replaced_bolts_nuts_count
Number of bolts and nuts replaced
- replaced_compression_cone_tick
TRUE if compression cone was replaced
- replaced_compression_cone_count
Number of compression cones replaced
- replaced_cylinder_tick
TRUE if cylinder was replaced
- replaced_cylinder_count
Number of cylinders replaced
- replaced_flapper_tick
TRUE if flapper was replaced
- replaced_flapper_count
Number of flappers replaced
- replaced_footvalve_bobbin_tick
TRUE if footvalve bobbin was replaced
- replaced_footvalve_bobbin_count
Number of footvalve bobbins replaced
- replaced_footvalve_body_tick
TRUE if footvalve body was replaced
- replaced_footvalve_body_count
Number of footvalve bodies replaced
- replaced_footvalve_oring_tick
TRUE if footvalve O-ring was replaced
- replaced_footvalve_oring_count
Number of O-rings replaced
- replaced_fulcrum_pin_tick
TRUE if fulcrum pin was replaced
- replaced_fulcrum_pin_count
Number of fulcrum pins replaced
- replaced_fulcrum_bearings_tick
TRUE if fulcrum bearings were replaced
- replaced_fulcrum_bearings_count
Number of fulcrum bearings replaced
- replaced_handle_tick
TRUE if handle was replaced
- replaced_handle_count
Number of handles replaced
- replaced_hanger_pin_tick
TRUE if hanger pin was replaced
- replaced_hanger_pin_count
Number of hanger pins replaced
- replaced_hanger_bearings_tick
TRUE if hanger bearings were replaced
- replaced_hanger_bearings_count
Number of hanger bearings replaced
- replaced_head_bolt_tick
TRUE if head bolt was replaced
- replaced_head_bolt_count
Number of head bolts replaced
- replaced_plunger_bobbin_tick
TRUE if plunger bobbin was replaced
- replaced_plunger_bobbin_count
Number of plunger bobbins replaced
- replaced_plunger_body_tick
TRUE if plunger body was replaced
- replaced_plunger_body_count
Number of plunger bodies replaced
- replaced_plunger_useal_tick
TRUE if plunger U-seal was replaced
- replaced_plunger_useal_count
Number of U-seals replaced
- replaced_pump_head_case_tick
TRUE if pump head case was replaced
- replaced_pump_head_case_count
Number of pump head cases replaced
- replaced_pump_head_cover_tick
TRUE if pump head cover was replaced
- replaced_pump_head_cover_count
Number of pump head covers replaced
- replaced_rising_main_tick
TRUE if rising main pipe was replaced
- replaced_rising_main_count
Number of rising main pipes replaced
- replaced_rising_centralisers_tick
TRUE if rising main centralisers were replaced
- replaced_rising_centralisers_count
Number of centralisers replaced
- replaced_rods_tick
TRUE if rods were replaced
- replaced_rods_count
Number of rods replaced
- replaced_rod_centralisers_tick
TRUE if rod centralisers were replaced
- replaced_rod_centralisers_count
Number of rod centralisers replaced
- replaced_rodhanger_tick
TRUE if rodhanger was replaced
- replaced_rodhanger_count
Number of rodhangers replaced
- replaced_rope_tick
TRUE if rope was replaced
- replaced_rope_count
Number of ropes replaced
- replaced_socket_tick
TRUE if socket was replaced
- replaced_socket_count
Number of sockets replaced
- replaced_steel_cone_tick
TRUE if steel cone was replaced
- replaced_steel_cone_count
Number of steel cones replaced
- replaced_top_sleeve_tick
TRUE if top sleeve was replaced
- replaced_top_sleeve_count
Number of top sleeves replaced
- functionality_after
Functional status of the water point after intervention
- time_to_fill_20l_bucket
Time (in seconds) it took to fill a 20L bucket
- strokes_to_yield_water
Number of strokes required to yield water from the pump